Nature protection technologies

1.2.1.1. Bases of fly ash collecting and particulate emission standards at TPPs

Part 1. AIR PROTECTION FROM POWER INDUSTRY EMISSIONS

1.2. Ash collecting at TPPs

1.2.1. Fly Ash collecting and particulate emission standards at TPPs

1.2.1.1. Bases of fly ash collecting and particulate emission standards at TPPs

Prokhorov V.B., MPEI (TU)

An efficiency of ash collector operation is characterized by the following indicator:

η = (Gin – Gout)/Gin = (cin – cout)/cin, (1.1)

where η is an ash collection efficiency; Gin, Gout is an amount of ash at the inlet and outlet of the dust collector in unit time; cin, cout is an ash concentration at the inlet and outlet of the dust collector.